Five Installation Mistakes That Cost an Explosion-Proof Camera Its Compliance
The certificate covers the assembled unit — housing, gland and blanking plug together. These five installation choices are the ones that most often turn a certified camera into a non-compliant one.
An explosion-proof camera is certified as a complete assembly — housing, cable entry, gland and blanking plug together. The certificate covers that assembly, not the camera body on its own.
Most site failures are therefore not camera failures. They come from installation choices that break the assembly after the camera has left the factory. Each mistake below is cheap to avoid at install time and expensive to correct after commissioning.
1. Fitting a gland that carries no Ex certification
The cable entry is part of the flameproof enclosure. A general-purpose industrial gland may seal against water and dust, but it does not preserve the flame path, and it is not covered by the enclosure's certificate.
Use a gland certified for the same protection concept as the enclosure — Ex d for a flameproof housing, Ex e for increased safety — and rated for the cable construction and diameter you are actually pulling. Where armoured cable is used, the gland must also terminate the armour correctly.
2. Damaging, corroding or painting the flame path
The machined joint between the housing and its cover is what contains an internal ignition and stops it reaching the surrounding atmosphere. Scratches, corrosion, paint build-up, a missing gasket or an incorrect O-ring all defeat it.
Keep the joint clean and unpainted unless the manufacturer's installation manual explicitly permits a specified coating. Torque the cover bolts to the value given in that manual, with the correct bolt grade — not by feel.
3. Leaving unused cable entries open
Every unused entry must be closed with a certified blanking or stopping plug of the same protection concept and thread form as the entry. An open entry, or one closed with a plain metal plug, leaves the enclosure non-compliant no matter what certificate the camera itself carries.
This is the most common finding on sites where cameras were installed with spare capacity for future cabling.
4. Inadequate earthing and bonding
The enclosure must be bonded into the plant's equipotential system using the earth facility provided by the manufacturer, with a conductor sized and terminated to the project specification.
Paint, anodising and surface corrosion can insulate a bonding point. Use the designated earth stud and the washer type specified by the project, then verify continuity rather than assuming it.
5. Opening the enclosure while it is energised
Flameproof does not mean safe to open. The enclosure may only be opened after the circuit has been isolated under the site's permit-to-work system, and in many cases after the manufacturer's stated discharge or cooling period.
Where a camera needs frequent adjustment, plan for it at design stage — remote configuration, an external wiper control, or a certified increased-safety enclosure for the termination — instead of accepting repeated hot openings as normal practice.
Commissioning checks before handover
- Confirm the Ex marking on the camera nameplate matches the zone, gas group and temperature class required by the area classification.
- Verify each gland and blanking plug carries its own Ex marking and certificate, for the same protection concept as the enclosure.
- Check that all cover bolts are present, of the correct grade, and torqued to the manufacturer's value.
- Confirm the earth or bond connection is made at the designated point and that continuity has been measured.
- Record the installation in the hazardous-area register with the certificate references for every certified component — not just the camera.
Frequently asked
- Can I use a standard IP68 gland on an Ex d camera?
- No. Ingress protection and explosion protection are separate properties assessed separately. The gland needs its own Ex certification for the protection concept in use, in addition to the IP rating the installation requires.
- Does the camera's certificate still apply if I change the gland?
- The certificate applies to the assembly as certified. Substituting a component that was not covered by that certificate can invalidate the installation. Check the certificate scope and the manufacturer's instructions before replacing any component.
- What should be recorded in the hazardous-area register?
- At minimum: the location and its zone, the camera model and Ex marking, the certificate numbers for the camera, the gland and any blanking plugs, and the inspection record. The detail is defined by your site's inspection regime, which is normally built on IEC 60079-17.
Related products
4MP 33× Explosion-Proof PTZ Dome IP Camera
4 MP explosion-proof PTZ dome camera with 33× optical zoom, 316L stainless steel housing and IP68 protection.
4MP Explosion-Proof IR Bullet Camera
Compact 4 MP explosion-proof fixed bullet camera with 316L housing, IP68 protection, 30 m infrared and 2.8 mm or 4 mm lens options.
4 MP 5× Explosion-Proof IR Bullet IP Camera
4 MP explosion-proof IP bullet camera with 5× motorised zoom, a 2.7–13.5 mm lens, 316L housing and 60 m infrared.
Related reading
Oil & Gas
Upstream, midstream and downstream operators needing certified surveillance in classified hazardous areas, well sites, tank farms and loading facilities.
Petrochemical
Refining, petrochemical and chemical processing sites where flammable atmospheres, corrosive chemicals and continuous operation drive equipment selection.
Offshore
Offshore platforms, FPSOs and rigs that require hazardous-area certified and marine-rated equipment in the same installation.
Explosion-Proof Camera Selection Guide
How to match Ex marking, zone, gas group and temperature class to your area classification before selecting a camera model.
ATEX vs IECEx for Hazardous-Area CCTV
What ATEX and IECEx certification cover, why certification is model-level rather than brand-level, and what to request from a supplier.
More from the blog
- TechnicalCondensation and Salt Spray on Marine Cameras: A Field Checklist
Fogged lenses and salt corrosion are almost never a camera defect. They trace back to a moisture path or a material mismatch — here is how to find which one, in order.
- Policy UpdateADNOC ICV Certification: What Suppliers Should Know Before Tendering
A practical ICV preparation checklist for suppliers: tender requirements, financial records, certification documents and renewal planning.